Przeglądanie stron 41
red
PELLET STOVES Chapter 5
INSTALLATION AND USE MANUAL
page 42
Maintenance and cleaning Technical service - Rights reserved - Reproduction prohibited
A
B
"T"JOINT
C
B
A
D
E
F
G
H
L
CLEANING THE UPPER COMPARTMENT - DALIA STOVE
When the stove is cold, raise the cover “A” and remove the steel top
“B” which is merely resting on top of some rubbers. Next, remove the
sides “C” as shown in Section 3.3.
Remove the other cover “D” which is secured to the structure by four
screws (two at the front and two at the rear), then slide out the
insulation panel “E” and remove the panel “F” unscrewing the two
screws on the right and the two screws on the left.
The surface below features a small plate “G” secured with two screws.
Remove this piece too and access the inspection hole for cleaning (see
arrow).
Using a stiff rod or a bottle brush, scrape the inner walls of the fire box
so that the ashes drop into the lower ash compartment. Clean and refit
all the components.
CLEANING THE LOWER COMPARTMENT
GARDENIA/MARGHERITA AND ORCHIDEA/PRIMULA STOVES
Clean as explained in section 5 around the grate “A”. Unscrew the 4
screws and remove cap “B” and with the vacuum cleaner nozzle
remove the ash and the soot accumulated in the lower exchanger
shown by the arrow.
CLEANING THE LOWER COMPARTMENT - DALIA STOVE
Clean as explained in section 5 around the grate “A”. Unscrew the 2
screws and remove the plug “L”. Then remove the plate “H” removing
the two screws and using the a vacuum cleaner nozzle remove the ash
and soot in the lower heat exchanger shown by the arrow.
CLEANING OF SMOKE DUCT AND GENERAL CHECKS:
Clean the smoke discharge system, especially in the area of the
tee connectors, curves and any horizontal stretches of pipe.
For information on cleaning the flue pipe, contact a professional
chimney sweep.
Check the seal of the ceramic fibre gaskets on the door of the stove. If
necessary, order new gaskets from the retailer for replacement or
contact an authorized service centre to carry out this work.
ATTENTION:
The frequency with which the smoke discharge
system is cleaned should be determined based on the
type of use that is made of the stove and the type of
installation.
We recommend relying on an authorized service
centre for end-of-season cleaning and maintenance,
they will carry out all of the previously mentioned
work and make a general check of the stove's
components.
Cleaning the lower compartment -
Gardenia/Margherita and Orchidea/Primula
Cleaning the upper/lower compartment - Dalia
stove